Related Experiment Video
Updated: Aug 10, 2026

The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
Published on: November 4, 2010
Colonic anastomotic stenoses and Memotherm stent fracture: a report of three cases
1Department of Radiology, Southhampton General Hospital, Southhampton SO16 6YD, UK. allan.odurny@suht.swest.nhs.uk
Abstract:
Deployment of a Memotherm colonic stent (Bard, Angiomed, Karlsruhe, Germany) across anastomotic strictures, following anterior resection, is described in three patients. Two patients presented with symptoms of colonic obstruction. Two of the patients had previously undergone unsuccessful balloon dilatation of the stricture. In the third, in addition to the anastomotic stricture, there was local tumor recurrence. Initially, stenting provided effective relief of symptoms. However, in all three patients, fracture of the stents occurred at intervals of 3-7 months after insertion. This use and complication of colonic stenting has not been reported previously.