Related Experiment Video
Updated: Jul 8, 2026

Techniques for Processing Eyes Implanted With a Retinal Prosthesis for Localized Histopathological Analysis
Published on: August 2, 2013
[Clinical practice of spherical allogeneic biological membranous implant in the eye socket]
1Department of Ophthalmology, Zhangjiakou Fourth Hospital, Zhangjiakou 075000.
Objective:
To investigate the effect of implantation of spherical allogeneic biological material implant after eyeball enucleation.
Methods:
A spherical allogeneic biological material implant was implanted in the eye socket after eyeball enucleation in 50 cases including stage I in 48 cases and stage II in 2 cases.
Results:
After operation, the motility of installed artificial eyes was good in 49 cases, the orbit and eyelids were full in all the cases. In the follow-up of 4 - 24 months (mean, 8 months), the conjunctival wound and muscular tissue were adherent firmly to the biological material, and there were no postoperative infection, no dislocation and shift of the implant.
Conclusion: