A computerised quality control testing system for B-mode ultrasound.

N M Gibson1, N J Dudley, K Griffith

  • 1Medical Physics Department, Nottingham City Hospital NHS Trust, Hucknall Road, Nottingham NG5 1PB, UK. ngibson@ncht.org.uk

Ultrasound in Medicine & Biology
|February 13, 2002
PubMed
Summary

This study introduces automated software for ultrasound (US) image quality control, significantly improving reproducibility over manual methods. The system accurately assesses image parameters like resolution and contrast sensitivity for better US scanner performance evaluation.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Ovarian function suppression decision-making and uptake in premenopausal women with breast cancer: a mixed methods analysis.

Breast cancer research and treatment·2026
Same author

Shifts in learning assistants' self-determination due to COVID-19 disruptions in Calculus II course delivery.

International journal of STEM education·2021
Same author

Progesterone signaling during pregnancy in the lab opossum, Monodelphis domestica.

Theriogenology·2019
Same author

Early experience with automated B-mode quality assurance tests.

Ultrasound (Leeds, England)·2016
Same author

A case study in scanner optimisation.

Ultrasound (Leeds, England)·2016
Same author

Perfusionist techniques of reducing acute kidney injury following cardiopulmonary bypass: an evidence-based review.

Perfusion·2014

Area of Science:

  • Medical Imaging
  • Ultrasound Technology
  • Quality Control

Background:

  • Current ultrasound (US) imaging quality control relies on labor-intensive, subjective manual measurements.
  • Increasing complexity of US scanners exacerbates the challenges of manual quality control.
  • Subjectivity in manual assessments leads to undesirable intraobserver and interobserver variations.

Purpose of the Study:

  • To develop and validate an automated software system for US image quality control.
  • To objectively estimate key performance parameters of US scanners.
  • To improve the reproducibility and accuracy of US imaging quality assessments.

Main Methods:

  • Development of a software suite to analyze captured US images.
  • Utilized the ATS Laboratories Multipurpose Phantom Model 539 for image acquisition.

Related Experiment Videos

  • Automated testing for resolution, high- and low-contrast penetration, and sensitivity.
  • Main Results:

    • Preliminary validation showed 95% confidence intervals for resolution (+/- 17% to +/- 21%) and low-contrast penetration (0% to +/- 1.5%).
    • The system provides an objective index of visibility for high- and low-contrast targets.
    • Confidence intervals for contrast sensitivity ranged from +/- 6% to +/- 25%.

    Conclusions:

    • The automated system offers improved reproducibility compared to human observers.
    • The software provides enhanced information on target visibility in US images.
    • Further multicenter validation is underway to confirm system efficacy.