Related Experiment Video
Updated: Oct 2, 2026

Tubal Cytology of the Fallopian Tube as a Promising Tool for Ovarian Cancer Early Detection
Published on: July 25, 2017
Assessment of Fallopian tube patency by HyCoSy: comparison of a positive contrast agent with saline solution
F P Boudghène1, M Bazot, Y Robert
1Department of Radiology, Hôpital Tenon, Université Paris 6, France. frank.boudghene@tnn.ap-hop-paris.fr
Objective:
To compare the efficiency of air-filled albumin microspheres (Infoson) with saline solution in determining Fallopian tube patency during hysterosalpingo contrast sonography (HyCoSy).
Methods:
This was a prospective randomized multicenter study with a sequential design. Over a 10-month period, 23 patients (mean age, 33 years) referred for infertility were examined by HyCoSy (saline or Infoson) before conventional hysterosalpingography (Iopamiron 370), performed during the same session. Contrast agents were administered through a 5-F Ackrad balloon catheter inserted transcervically into the uterine cavity. HyCoSy was performed with a 7-MHz transvaginal probe using both B-mode and color Doppler, and tubal patency was demonstrated by the appearance of contrast agent in the peritoneal cavity near the ovaries. Data were registered for each patient during the examination and the results were monitored by sequential analysis.
Results:
Mean volumes of contrast injections were 35.3 mL of saline, 14.4 mL of Infoson, and 13.8 mL of Iopamiron 370. Infoson-enhanced HyCoSy provided a significantly larger (P = 0.006) number of correct diagnoses (20/22 Fallopian tubes) than did saline HyCoSy (12/24 Fallopian tubes), and the same number as that achieved by hysterosalpingography.
Conclusion:
A positive ultrasound contrast agent appears to be more efficient than saline solution at determining Fallopian tube patency in infertile women by means of HyCoSy, and as efficient as an iodinated contrast agent in the same population explored by HSG. HyCoSy could be used to screen infertile women, thereby avoiding the use of iodinated contrast medium and exposure to ionizing radiation during conventional HSG in patients with patent Fallopian tubes.
Related Concept Videos
Urologic Endoscopic Procedure: Cystoscopic Examination
Uterine Tubes
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies V: Intravenous Urography and Retrograde Pyelography
Imaging Studies II: Ultrasonography
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...

