Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system

Yili Wang1, Jinlong Guo, Hongxiao Tang

  • 1State Key Laboratory of Environmental Aquatic Chemistry, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, P R China. wangyilinet@sina.com

Related Concept Videos

Bioreactor Design and Operational System01:29

Bioreactor Design and Operational System

Bioreactors are engineered vessels designed to cultivate microorganisms under controlled conditions for industrial bioprocessing. They maintain sterility and allow precise regulation of pH, temperature, oxygen, and nutrient levels to optimize microbial growth and metabolite production. Bioreactors range from small laboratory units of 1 liter to industrial systems holding up to 500,000 liters, though only about 75% of their volume is actively used for fermentation. The remaining headspace...
30
Bioreactor Controls-II01:18

Bioreactor Controls-II

In aerobic fermentations, oxygen is vital for microbial growth and metabolite production. Since air comprises only about 20% oxygen and the gas is poorly soluble in water—just 9 ppm at 20°C—supplying sufficient oxygen becomes a critical challenge, especially in high-demand processes like yeast growth or citric acid production. Even a fully saturated broth may offer only a few seconds of oxygen availability.To address this, sterile or scrubbed air is introduced into the...
13
Coagulation01:06

Coagulation

Colloidal solids are solid particles suspended in solution. They are usually negatively charged, attracting a compact primary layer of positively charged ions, which attract more counterions to form an electrical double layer. Electrostatic repulsion between the charged double layers prevents the particles from colliding, stabilizing the colloids. These solids are often undesirable because they can contain toxins that are difficult to remove. Coagulation is a technique that helps aggregate and...
1.6K
Testing Water Quality01:14

Testing Water Quality

When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
451