Prospective evaluation of delayed technetium-99m sestamibi SPECT scintigraphy for preoperative localization of
A Cahid Civelek1, Elcin Ozalp, Patricia Donovan
1Russell H. Morgan Department of Radiology and Radiological Science, Division of Nuclear Medicine, The Johns Hopkins Medical Institutions, Baltimore, MD, USA.
Background:
Delayed technetium-99m sestamibi single photon emission computed tomography (SPECT) scans were prospectively analyzed in a large series of patients with primary hyperparathyroidism.
Methods:
Three hundred thirty-eight patients underwent sestamibi-SPECT and were explored. Prospective data included preoperative demographics, clinical, sestamibi, and operative findings, laboratory values, and pathologic and follow-up laboratory results from all patients.
Results:
Between 1994 and 2000, 287 unexplored patients (85%) and 51 re-explored patients (15%) participated. The abnormal parathyroid glands excised from 336 of 338 patients included 299 single adenomas (88%) and 23 double adenomas (7%), and 14 patients had multigland hyperplasia (4%). Sestamibi SPECT correctly lateralized 349 of 400 abnormal parathyroid glands, with an overall sensitivity of 87%, an accuracy of 94%, and a positive predictive value of 86%. Precise localization occurred in 82% of the abnormal parathyroid glands. Sestamibi sensitivity was similar in unexplored (87%) and reoperative (92%) cases; two hundred eighty-six of 299 (96%) solitary adenomas, 38 of 46 (83%) double adenomas, but only 25 of 55 (45%) hyperplastic glands were identified. The mean weight of the true-positive glands (1252 +/- 1980 mg) was greater than that of the false-negative glands (297 +/- 286 mg) (P <.005). Three patients had persistent primary hyperparathyroidism, in spite of the excision of sestamibi-identified lesions in 2 cases. Follow-up indicated curative resection in 99% of the unexplored cases and 94% of the remedial cases.
Conclusions:
Sestamibi SPECT is highly accurate for the localization of parathyroid adenomas in unexplored and re-explored cases, where it is often the only imaging required. Its sensitivity is limited in multiglandular disease.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies III: Computed Tomography