Micellar liquid chromatography: suitable technique for screening analysis
Related Experiment Video
Updated: Oct 2, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
M J Ruiz-Angel1, R D Caballero, E F Simó-Alfonso
1Departamento de Química Analítica, Facultad de Química, Universitat de València, Burjassot, Spain.
Abstract:
The screening capability of micellar liquid chromatography (MLC) is discussed using the reported chromatographic data of several sets of compounds (amino acids, beta-blockers, diuretics, phenethylamines, phenols, polynuclear aromatic hydrocarbons, steroids and sulfonamides) and new results (sulfonamides and steroids). The chromatographic data are treated with an interpretive optimisation resolution procedure to obtain the best separation conditions. Usually, the pH and the concentration of surfactant (sodium dodecyl sulfate, SDS, or cetyltrimethylammonium bromide) for the optimal mobile phase were 2.5-3 and < 0.12 M, respectively. The nature and concentration of organic solvent depended on the polarity of the eluted compounds: a low volume fraction of propanol (approximately 1%, v/v) was useful to separate the amino acids, with log P(o/w) < -1 (where P(o/w) is the octanol-water partition coefficient). A greater concentration of this solvent (approximately 5-7%) was needed for compounds in the range -1 < log P(o/w) < 2, as with the studied diuretics and sulfonamides, and a high concentration of propanol (approximately 15%) or a low concentration of butanol (< 10%) had to be used for less polar compounds with 1 < log P(o/w) < 3, such as the beta-blockers. Pentanol (< 6%) was more suitable for the even less polar compounds with log P(o/w) > 3, such as the steroids. For basic drugs such as the phenethylamines (0 < log P(o/w) < 1.7), eluted with a micellar eluent of anionic SDS, propanol was too weak. A study is also shown for mixtures of sulfonamides (log P(o/w) = -1.2 to 1.7) and steroids (log P(o/w) = 3.0-8.1) eluted from conventional C18 columns with SDS mobile phases containing acetonitrile and 1-pentanol, respectively, which are compared with classical acetonitrile-water and methanol-water mixtures. The results complement a previous study on beta-blockers (log P(o/w) = -0.03 to 2.8) and reveal that MLC is a very competitive technique for the screening of compounds against conventional RPLC, due to its peculiar behaviour with regard to the selectivity and elution strength. The concentration of organic solvent needed to obtain sufficiently low retention times (even for highly hydrophobic steroids with log P(o/w) = 7-8) is also appreciably smaller for MLC, which reduces the environmental impact of the mobile phases.
More Related Videos
14:42Liquid Chromatography Coupled to Refractive Index or Mass Spectrometric Detection for Metabolite Profiling in Lysate-based Cell-free Systems
Published on: September 23, 2021
11:00Untargeted Metabolomics from Biological Sources Using Ultraperformance Liquid Chromatography-High Resolution Mass Spectrometry (UPLC-HRMS)
Published on: May 20, 2013
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...