Related Experiment Video
Updated: Oct 2, 2026

Multifocal Electroretinograms
Published on: December 4, 2011
Detection using the multifocal electroretinogram of mosaic retinal dysfunction in carriers of X-linked retinitis
Thasarat S Vajaranant1, William Seiple, Janet P Szlyk
1Department of Ophthalmology and Visual Science, University of Illinois at Chicago, 1855 West Taylor Street, Chicago, IL 60612, USA.
Purpose:
To examine whether a mosaic pattern of retinal dysfunction in obligate carriers of X-linked retinitis pigmentosa (XLRP) could be observed in local electroretinographic responses obtained with the multifocal electroretinogram (mfERG).
Design:
Prospective observational case series.
Participants:
Five obligate carriers of XLRP (mean age, 53.2 years) were recruited into the study.
Methods:
Examination of each subject included a complete ocular examination, Humphrey visual field, standard full-field electroretinogram (ERG), and mfERG testing. For the mfERG, we used a 103-scaled hexagonal stimulus array that subtended a retinal area of approximately 40 in diameter. The amplitudes and implicit times in each location for the mfERG was compared with the corresponding value determined for a group of normally sighted, age-corrected control subjects.
Main Outcome Measures:
Mapping of 103 local electroretinographic response amplitudes and implicit times within the central 40 with the multifocal electroretinogram.
Results:
Localized regions of reduced mfERG amplitudes and/or delayed implicit times were found in four of five carriers. In one of these four carriers, a mosaic pattern of mfERG dysfunction was present even in the absence of any clinically apparent retinal changes, retinal sensitivity losses on Humphrey field testing, or abnormal full-field cone ERG responses. However, one carrier with a typical tapetal-like reflex demonstrated no deficit on any functional tests.
Conclusions:
The mfERG demonstrated patchy areas of retinal dysfunction in some carriers of XLRP. This mosaic pattern of dysfunction may be observed in some patients with a normal-appearing fundus, normal psychophysical thresholds, and normal amplitude and implicit time full-field ERG cone responses.