[Multi-slice spiral CT: 3D CT angiography for evaluating therapeutically relevant stenosis in peripheral arterial
1Klinik für Strahlenheilkunde, Campus Virchow Klinikum, Berlin. puls@charite.de
Purpose:
Evaluation of 3D multislice CT angiography for the assessment of relevant stenoses of pelvic arteries and arteries of the lower extremity in patients with peripheral artery occlusive disease compared to digital subtraction angiography.
Method/Materials:
For this study we examined 31 patients with peripheral artery occlusive disease. All patients received a multislice helical CT angiography and arterial digital subtraction angiography. Multislice CT angiography was performed with a Somatom Plus 4 Volume Zoom (Siemens, Erlangen, Germany). After test bolus injection of 20 ml Ultravist 370 (Schering AG, Berlin) additional 150 ml were applied with a flow rate of 3 ml/sec and a scan delay between 20-35 sec depending on individual blood circulation time. Collimation was 4 x 2.5 mm with a pitch of 6. Reconstructed slice thickness was 3 mm. 3D reconstructions of arteries of pelvic and lower extremity arteries were performed in volume rendering technique on a 3D Virtuoso workstation (Siemens, Erlangen).
Results:
For the assessment of therapeutically relevant stenoses (over 50% reduction of luminal diameter) multislice CT achieved the following results compared to conventional angiography for the diagnosis of stenosis: sensitivity of 86%, specificity of 86% and an accuracy of 72%.
Conclusions:
Multislice helical CT angiography of pelvic arteries and arteries of the thigh represents a reliable means for the detection of relevant stenoses in patients with peripheral occlusive artery disease.
More Related Videos
09:32Time-Resolved, Dynamic Computed Tomography Angiography for Characterization of Aortic Endoleaks and Treatment Guidance via 2D-3D Fusion-Imaging
Published on: December 9, 2021
09:36A Magnetic Resonance Imaging-based Computational Protocol for Analysis of Plaque Morphology and Hemodynamics in Patients with Carotid Artery Stenosis
Published on: August 12, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation