Inspired gas temperature during mechanical ventilation: effects of environmental temperature and airway temperature
1Department of Neonatology, Westmead Hospital, Sydney, New South Wales, Australia. David@thetodds.enterprise-plc.com
Objectives:
To determine the inspired gas temperature during mechanical ventilation with: (i) five different humidicrib temperatures; (ii) two airway temperature probe (ATP) positions; and (iii) four ATP adaptors.
Methodology:
An observational study in the Neonatal Intensive Care Laboratory, Westmead Hospital. The inspired gas temperature was measured at the proximal end of the endotracheal tube (ETT) during conventional mechanical ventilation using a Tele-thermometer. Inspired gas temperature measurements were made with: (i) the humidicrib temperature set at 30.8. 32.9, 35.2, 36.2. or 37.2 degrees C; (ii) the ATP either (A) positioned inside the humidicrib at the distal end of the inspiratory tubing or (B) positioned outside the humidicrib 50 cm proximal to the ETT, with the inspired gas temperatures set at 36.5 and 39.0 degrees C, respectively; and (iii) the measurements repeated with four different ATP adaptors at each humidicrib temperature and each ATP position.
Results:
With the ATP inside the humidicrib, there were no significant differences between set and actual inspired gas temperature. However, with the ATP outside the humidicrib, there were significant decreases in inspired gas temperature at each humidicrib temperature. For instance, with the ATP outside the humidicrib and set at 39.0 degrees C, the inspired gas temperature decreased to 34.7+/-0.2 degrees C at a humidicrib temperature of 30.8 degrees C and to 37.7+/-0.2 degrees C at a humidicrib temperature of 37.2 degrees C. The type of ATP adaptor also had a significant effect on inspired gas temperature.
Conclusions:
With the ATP placed outside the humidicrib and with variations of humidicrib temperature, infants are likely to have inspired gas temperatures that are significantly different to the desired temperature. Certain ATP adaptors cause these variations in inspired gas temperature to be more pronounced. Extreme care must be used to avoid suboptimal inspired gas temperatures with these environmental variations and the ATP positioned outside the humidicrib.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Mechanical Ventilation I: Indication and Settings
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation (NIPPV)