Related Experiment Videos
Fixed mandibular restorations on three early-loaded regular platform Brånemark implants
H De Bruyn1, J Kisch, B Collaert
1Centre Periodontology and Implantology, Brussels, Belgium. hugo.debruyn@glo.be
Clinical Implant Dentistry and Related Research
|March 13, 2002
Summary
This study found that using only three implants for a fixed mandibular bridge resulted in a 9.5% failure rate. This early-loading, one-stage surgery approach is less successful than standard multi-implant restorations.
Area of Science:
- Oral and Maxillofacial Surgery
- Dental Implantology
- Prosthodontics
Background:
- The Brånemark System, initially a two-stage procedure, has evolved with one-stage and early-loading options for edentulous mandibles.
- Reducing surgical interventions and implant numbers can decrease patient financial burden.
- Patient financial concerns are a significant factor in implant treatment decisions.
Purpose of the Study:
- To evaluate the 1- and 3-year success rates of mandibular implants loaded within one month after one-stage surgery.
- To assess the prosthetic outcomes of fixed 10- to 12-unit bridges supported by three Brånemark System implants.
- To gather patient perspectives on the early-loading, one-stage implant procedure.
Main Methods:
- A prospective multicenter study involving 20 patients with edentulous mandibles.
- Functionally loading three regular platform Brånemark System implants in a tripodal position within one month of one-stage surgery.
- Utilizing two additional control implants (one-stage and submerged) for comparative analysis of stability and bone levels.
Main Results:
- A 9.5% cumulative implant failure rate was observed after 1 and 3 years in the functionally loaded group (group 1).
- Six of 60 loaded implants (10%) and 3 of 20 prostheses (15%) failed within the first year.
- Marginal bone loss was observed, with average levels at 3 years being 2.1 mm for group 1, 2.4 mm for group 2, and 0.7 mm for group 3.
Conclusions:
- The use of three Brånemark System implants for a fixed mandibular reconstruction with early loading showed less favorable results compared to standard protocols.
- This treatment approach may not achieve the success rates expected with conventional four- to six-implant restorations.
- Further research may be needed to optimize protocols for reduced implant number and early loading in mandibular reconstructions.