Related Experiment Video
Updated: Jul 29, 2026

Non-invasive Assessment of Microvascular and Endothelial Function
Published on: January 29, 2013
The radial hyperaemic response: a new and objective assessment of ulnar collateral supply to the hand
1Division of Cardiac Surgery, University Hospitals Leicester, Glenfield Hospital, UK.
The assessment of adequate ulnar collateral supply to the hand is mandatory prior to the harvest of the radial artery as a conduit for coronary artery bypass grafting. However, there is currently no one test which is widely used in all centres. We report a new and objective method of assessing ulnar collateral supply to the hand prior to harvest of the radial artery. This technique involves assessing the presence of a hyperaemic flow response to occlusion of the radial artery using an intraoperative transit time flowmeter. We found this technique to be objective and reliable, and would advocate its use in patients with a positive Allen's test.
The assessment of adequate ulnar collateral supply to the hand is mandatory prior to the harvest of the radial artery as a conduit for coronary artery bypass grafting. However, there is currently no one test which is widely used in all centres. We report a new and objective method of assessing ulnar collateral supply to the hand prior to harvest of the radial artery. This technique involves assessing the presence of a hyperaemic flow response to occlusion of the radial artery using an intraoperative transit time flowmeter. We found this technique to be objective and reliable, and would advocate its use in patients with a positive Allen's test.
More Related Videos
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Bones of the Upper Limb: Ulna
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Arteries of the Upper Limbs
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...

