Related Experiment Video
Updated: Jul 27, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Iodixanol in paediatric gastrointestinal imaging: safety and efficacy comparison with iohexol
N B Wright1, H M L Carty, A Sprigg
1Department of Paediatric Radiology, Royal Manchester & Booth Hall Children's Hospital, Manchester, UK.
Abstract:
Iodixanol (Visipaque) is a dimeric, non-ionic iodinated contrast medium that is isotonic with blood at all clinically relevant concentrations. Iodixanol was compared in a randomized, double blind, parallel group, phase III multicentre trial with a monomeric, non-ionic contrast medium, iohexol (Omnipaque), at two concentrations assessing safety, tolerability and radiographic efficacy during contrast enhanced gastrointestinal radiography examinations of children. 154 children entered the trial; 152 formed the safety population and 147 the efficacy population. All examinations were performed following standard departmental practice. Children were assigned into either a high or low concentration group (iodixanol, 150 mgI ml(-1) and 320 mgI ml(-1) vs iohexol, 140 mgI ml(-1) and 300 mgI ml(-1)). The primary outcome measure for efficacy was the overall quality of visualization, which was assessed using a 100 mm visual analogue scale (VAS). The secondary efficacy variables assessed were quality of contrast opacification, mucosal coating and overall quality of diagnostic information. Safety evaluation involved patient follow-up for at least 48 h. Taste acceptance was also assessed. There was no statistically significant difference between the two contrast media with regard to the primary and secondary efficacy variables assessed, although higher ratings were observed for iodixanol. The 100 mm VAS score overall was 86 mm for iodixanol and 82 mm for iohexol (95% confidence interval -2.56, 10.42). The frequency of adverse events was lower for patients receiving iodixanol. Adverse events, mainly diarrhoea, occurred in 12 patients (16.2%) in the iodixanol group and 28 patients (35.9%) in the iohexol group. This reached statistical significance (p=0.006). Overall, iodixanol is well suited for examinations of the gastrointestinal tract, giving good efficacy results and fewer adverse events than iohexol.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Drug Dosing: Infants and Children
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies III: Computed Tomography

