Related Experiment Video
Updated: Oct 2, 2026

Clinical Imaging of Microwave Mammography
Published on: November 14, 2025
Non-invasive temperature profile estimation in a lossy medium based on multi-band radiometric signals sensed by a
1Electrical Engineering Group, Institute of Physics, Faculty of Science, University of Tromsø, Norway. svein.jacobsen@phys.uit.no
Abstract:
Microwave radiometry has during the past two decades been investigated as a non-invasive scheme for measurement of subcutaneous tissue temperatures, basically for monitoring and control in hyperthermic treatment of cancer. In this effort, we test a contact-type, dual-purpose antenna with integral water bolus. To overcome conflicting optimization criteria in the integration of this thermometry technique with heat applicators exhibiting a large effective field size during superficial hyperthermia, a stacked configuration design is proposed, where the radiometer receive antenna (Archimedean spiral) is located on the front (skin) surface of the water bolus and the heating antenna (Dual-Concentric Conductor aperture) is placed on the bolus back surface. The motivation is to achieve homogeneous tissue heating simultaneously with non-invasive thermography of the target tissue under the applicator. This paper addresses the feasibility of predicting one-dimensional depth temperature profiles from multi-band brightness temperatures. The performance is investigated statistically by a Monte Carlo technique on both simulated and real heated-phantom data using up to six radiometric bands. Analysis of measured data shows that during the transient heating period in a solid lossy phantom, the inversion technique exhibits a precision (2sigmaT) and skewness (bias) of estimated compared to actual temperature profiles of better than +/-0.38 degrees C and +/-0.55 degrees C, respectively.
Related Concept Videos
Absorption of Radiation
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

