Pacing in the middle cardiac vein in a patient with tricuspid prosthesis
Related Experiment Video
Updated: Oct 2, 2026

Upper-extremity Approach for Secondary Access in Transfemoral Transcatheter Aortic Valve Implantation
Published on: August 8, 2025
Luc S Nguyen1, Satinder Swaroop, Curtis A Prejean
1Department of Cardiology, Fountain Valley Regional Hospital, California, USA. lucsinh@dnamail.com
Abstract:
A man with acute endocarditis developed complete heart block several days after the tricuspid and aortic valve replacement. Several weeks after implantation, his epimyocardial pacing leads developed a high threshold and failed to capture the ventricle at the maximal pulse width and output of the pacemaker. An angled-tip lead was placed in the middle cardiac vein for ventricular pacing. The pacing and sensing thresholds of this lead were within the expected range during follow-up. Therefore, in patients with prosthetic tricuspid valve, pacing in the middle cardiac vein should be considered before open-chest placement of the epimyocardial lead.
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization IV: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send blood...
Mitral Valve Prolapse III: Nursing Management