A case study to detect the leakage of underground pressureless cement sewage water pipe using GPR, electrical, and
Guanqun Liu1, Yonggang Jia, Hongjun Liu
1Department of Environmental Engineering, College of Geoscience, Ocean University of Qingdao, Shandong, PR China. envcon@mail.ouqd.edu.cn
Abstract:
The exploration and determination of leakage of underground pressureless nonmetallic pipes is difficult to deal with. A comprehensive method combining Ground Penetrating Rader (GPR), electric potential survey and geochemical survey is introduced in the leakage detection of an underground pressureless nonmetallic sewage pipe in this paper. Theoretically, in the influencing scope of a leakage spot, the obvious changes of the electromagnetic properties and the physical-chemical properties of the underground media will be reflected as anomalies in GPR and electrical survey plots. The advantages of GPR and electrical survey are fast and accurate in detection of anomaly scope. In-situ analysis of the geophysical surveys can guide the geochemical survey. Then water and soil sampling and analyzing can be the evidence for judging the anomaly is caused by pipe leakage or not. On the basis of previous tests and practical surveys, the GPR waveforms, electric potential curves, contour maps, and chemical survey results are all classified into three types according to the extent or indexes of anomalies in orderto find out the leakage spots. When three survey methods all show their anomalies as type I in an anomalous spot, this spot is suspected as the most possible leakage location. Otherwise, it will be down grade suspected point. The suspect leakage spots should be confirmed by referring the site conditions because some anomalies are caused other factors. The excavation afterward proved that the method for determining the suspected location by anomaly type is effective and economic. Comprehensive method of GRP, electric potential survey, and geochemical survey is one of the effective methods in the leakage detection of underground nonmetallic pressureless pipe with its advantages of being fast and accurate.
Related Concept Videos
Plane Potential Flows
Uniform Flow
Uniform flow...
Permeability of Concrete
Pipe Flowrate Measurement: Problem Solving
Bernoulli's Equation: Problem Solving
The first step is to compute the cross-sectional areas of the pipe and the Venturi throat to analyze the pressure difference indicated by the pressure gauge. Next, the continuity equation is...
Pipe Flowrate Measurement
The orifice meter is a simple,...
Testing Water Quality