Related Experiment Video
Updated: Aug 14, 2026

Selective Labelling of Cell-surface Proteins using CyDye DIGE Fluor Minimal Dyes
Published on: November 26, 2008
Fluorescence-labeled peptide pI markers for capillary isoelectric focusing
Kiyohito Shimura1, Kei-ichiro Kamiya, Hiroyuki Matsumoto
1Faculty of Pharmaceutical Sciences, Teikyo University, Sagamiko, Kanagawa, Japan. shimurak@pharm.teikyo-u.ac.jp
Abstract:
Nineteen fluorescent pH standards or pI markers ranging pH 3.64-10.12 were developed for use in capillary isoelectric focusing using laser-induced fluorescence detection. Tetra- to tridecapeptides containing one cysteine residue were designed to focus sharply at their respective isoelectric points by including amino acids that contain charged side chains, the pKa values of which are close to the corresponding pI values. An iodoacetylated derivative of tetramethylrhodamine was coupled to the thiol group of cysteine to yield fluorescent pI markers. The pI values of the labeled peptides were precisely determined after isoelectric focusing on polyacrylamide gel slabs by direct measurement of the pH of the focused bands. The markers were subjected to capillary isoelectric focusing for 10-15 min in coated capillaries under conditions of low electroosmosis and were detected by means of a scanning laser-induced fluorescence detector down to a level of subpicomolar range. The markers permitted the calibration of a wide-range pH gradient formed in a capillary by fluorescence detection for the first time and should facilitate the development of highly sensitive analytical methods based on a combination of capillary isoelectric focusing and laser-induced fluorescence detection.
Related Concept Videos
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Protein Dynamics in Living Cells
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...