Voltage-dependence of ion permeation in cyclic GMP-gated ion channels is optimized for cell function in rod and cone photoreceptors
Related Experiment Video
Updated: Oct 1, 2026

Whole-cell Patch-clamp Recordings for Electrophysiological Determination of Ion Selectivity in Channelrhodopsins
Published on: May 22, 2017
Tsuyoshi Ohyama1, Arturo Picones, Juan I Korenbrot
1Department of Physiology, University of California at San Francisco School of Medicine, San Francisco, CA 94143, USA.
Abstract:
The kinetics of the photocurrent in both rod and cone retinal photoreceptors are independent of membrane voltage over the physiological range (-30 to -65 mV). This is surprising since the photocurrent time course is regulated by the influx of Ca(2+) through cGMP-gated ion channels (CNG) and the force driving this flux changes with membrane voltage. To understand this paradigm, we measured Pf, the fraction of the cyclic nucleotide-gated current specifically carried by Ca(2+) in intact, isolated photoreceptors. To measure Pf we activated CNG channels by suddenly increasing free 8-Br-cGMP in the cytoplasm of rods or cones loaded with a caged ester of the cyclic nucleotide. Simultaneous with the uncaging flash, we measured the cyclic nucleotide-dependent changes in membrane current and fluorescence of the Ca(2+) binding dye, Fura-2, also loaded into the cells. We determined Pf under physiological solutions at various holding membrane voltages between -65 and -25 mV. Pf is larger in cones than in rods, but in both photoreceptor types its value is independent of membrane voltage over the range tested. This biophysical feature of the CNG channels offers a functional advantage since it insures that the kinetics of the phototransduction current are controlled by light, and not by membrane voltage. To explain our observation, we developed a rate theory model of ion permeation through CNG channels that assumes the existence of two ion binding sites within the permeation pore. To assign values to the kinetic rates in the model, we measured experimental I-V curves in membrane patches of rods and cones over the voltage range -90 to 90 mV in the presence of simple biionic solutions at different concentrations. We optimized the fit between simulated and experimental data. Model simulations describe well experimental photocurrents measured under physiological solutions in intact cones and are consistent with the voltage-independence of Pf, a feature that is optimized for the function of the channel in photoreceptors.
Related Concept Videos
G-Protein Gated Ion Channels
Sensory organs,...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Voltage-gated Ion Channels
Generally, all voltage-gated ion channels have a 'voltage-sensing domain' that spans the lipid bilayer. The charged residues in the sensor move in response to the membrane potential changes that open the channel allowing ions movement. There are several types of...
Ligand-Gated Ion Channel Receptor: Gating Mechanism
Non-gated Ion Channels
Compared to the gated ion channels, the non-gated channels, also known as leakage or passive channels, have no gating mechanism.
Channel Rhodopsins
Rhodopsins belong to the family of cell surface proteins called G-protein coupled receptors,...