Colorectal polyp detection with virtual colonoscopy (computed tomographic colonography); the reliability of the method
Related Experiment Video
Updated: Oct 1, 2026

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
D Xynopoulos1, M Stasinopoulou, D Dimitroulopoulos
1Gastroenterology Department, Saint Savvas Anticancer Hospital, Athens, Greece.
Background/Aims:
The aim of this study was to compare the reliability of virtual colonoscopy with conventional colonoscopy in detection of colorectal polyps.
Methodology:
Between November 1997 and February 2000, 23 patients (14 males, 9 females) aged 43-86 years (mean: 63) with colorectal polyps who underwent colonoscopy in our endoscopy unit, were referred for virtual colonoscopy. The colon was distended with an enema tube for rectal insufflation and subsequently was scanned by helical CT (Toshiba X-vision) using the following parameters: KV 120, mAs 200, table feed 5 mm/sec, slice thickness 5 mm and reconstruction intervals 2.5 mm. Using SPARC Station 20, virtual colonoscopy was generated.
Results:
A total of 30 polyps (19 with diameter 8-15 mm and 11 larger than 15 mm) were detected with conventional colonoscopy. Virtual colonoscopy visualized 27 polyps (17 with diameter 8-15 mm and 10 with diameter > 15 mm).
Conclusions:
Virtual colonoscopy is a non-invasive, well-tolerated, safe technique and can be useful for detection of colorectal polyps. Weaknesses of the method are the inability to detect small lesions and to perform biopsies.
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
