Related Experiment Video
Updated: Aug 13, 2026

Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
Evaluation of a new method for the carotid pulse check in cardiopulmonary resuscitation
Colin A Graham1, Noreen F Lewis
1Accident and Emergency Medicine, Southern General Hospital, Glasgow, UK. colingrahamlt@ukonline.co.uk
Background:
The ability to determine the presence or absence of a central pulse remains a key skill in cardiopulmonary resuscitation (CPR) for healthcare providers, despite studies showing that they perform this poorly. The aim of this study was to evaluate a modified technique for palpation of the carotid pulse.
Methods:
Sixty seven undergraduate dental students were taught the standard method of carotid pulse detection during a basic life support session and were also taught a modified method. Each student was asked to palpate the carotid pulse of a volunteer in two positions (neck neutral and neck extended) with the volunteer on the floor and on a trolley. The time taken to identify the pulse was measured and the scenarios compared.
Results:
The time to detect the carotid pulse was reduced in three of the four scenarios (floor, neck extended P=0.0053, trolley neck neutral P=0.0070, trolley neck extended P=0.0024). The final scenario (floor, neck neutral) showed no improvement (P=0.36).
Conclusion:
The new method of carotid pulse palpation results in a more rapid determination of the carotid pulse when it is present in all positions except with the neck neutral on the floor. This will only be clinically significant if trauma is suspected.
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Special considerations while measuring pulse
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...
Cardiopulmonary Resuscitation I: Adult