Determination of the noise source in the electrocardiogram during cardiopulmonary resuscitation
Elaine Fitzgibbon1, Ronald Berger, Joshua Tsitlik
1Division of Cardiology, the Department of Medicine, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA.
Abstract:
During cardiopulmonary resuscitation (CPR), the electrocardiogram (ECG) is often obscured by noise. This noise is in the form of baseline variations in the ECG, which often necessitate stopping chest compressions to adequately assess the ECG. Because survival from cardiac arrest has been shown to be related to blood flow generated during CPR, and because interruption of chest compressions will reduce blood flow, survival may be compromised by these interruptions. Three possible sources for the noise were considered: the heart, which is deformed during CPR, which may introduce a mechanical-electrical interaction and alter the normal electrical pattern of the heart; the thoracic cavity, which may have large impedance variations because of CPR and thereby modulate the ECG; and the skin-electrode interface, which may be mechanically disturbed during CPR and thus produce polarization potentials that cause additional noise. CPR studies were performed on five dogs by using four different test conditions and six different types of electrodes. The test conditions were: electrode motion, which allowed mechanical disturbances of the skin-electrode interface without altering the thoracic impedance or deforming the heart; vest CPR; manual CPR; and respiration. The myocardial ECG, the bipolar and unipolar surface ECGs, and the thoracic impedance were monitored. Different types of surface ECG electrodes were used to determine whether the noise was dependent on electrode type or size. There were no baseline variations in the myocardial ECG during any of the test conditions. The thoracic impedance did vary during CPR, but the variations were temporally uncorrelated to the baseline variations in the ECG, and the variations were of similar magnitude as the variations caused by respiration, which produced no baseline changes in the ECG. Finally, the magnitude of the baseline variations in the ECG was substantially different for electrodes of different sizes and shapes, and electrode motion produced baseline variations that were identical to those produced during CPR. Therefore, it was concluded that the source of the noise in the ECG during CPR is the skin-electrode interface and, specifically, that the noise is related to the electrical properties of the electrode.
Related Concept Videos
Cardiopulmonary Resuscitation III: AED Use
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation IV: Pharmacological Management
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin to...