Relationship of AcrySof acrylic and PhacoFlex silicone intraocular lenses to visual acuity and posterior capsule
Michael T Halpern1, Dave Covert, Carmelina Battista
1Exponent, Inc., Alexandria, Virginia 22314, USA. mhalpern@exponent.com
Purpose:
To compare the changes in visual acuity and the development of posterior capsule opacification (PCO) with AcrySof acrylic intraocular lenses (IOLs) (Alcon Laboratories) and second-generation PhacoFlex silicone IOLs (Allergan ).
Setting:
Eye Associates of New Mexico and Southwest Colorado, Albuquerque, New Mexico, USA.
Methods:
Medical charts of patients having cataract extraction with implantation of an AcrySof MA30BA or MA60BM (MA30/60) or PhacoFlex SI-30NB or SI-40NB (SI-30/40) IOL between January 1995 and June 1997 were abstracted. Analyzed were the changes in visual acuity and development of PCO 1 month postoperatively and at the last available ophthalmologist visit or the visit before neodymium:YAG (Nd:YAG) capsulotomy.
Results:
Patients with MA30/60 acrylic IOLs were significantly older, had a worse preoperative best corrected visual acuity (BCVA), and had more concomitant ocular diseases than those with SI-30/40 silicone IOLs. The change in BCVA from preoperatively to 1 month postoperatively was equivalent in the 2 lens groups. The BCVA declined from 1 month postoperatively to the last recorded or pre-Nd:YAG visit. This decline was greater in eyes with SI-30/40 silicone IOLs than in those with MA30/60 acrylic IOLs. Although the decrease in BCVA between IOL types was not significantly different, eyes with a SI-30/40 silicone IOL were significantly more likely to develop PCO and have Nd:YAG capsulotomy. Eyes developing PCO had a statistically significant decline in BCVA from 1 month postoperatively to the last/pre-Nd:YAG visit.
Conclusions:
The MA30/60 acrylic lenses were associated with lower PCO and Nd:YAG capsulotomy rates than second-generation SI-30/40 silicone IOLs. Patients with MA30/60 IOLs also tended to have less of a decrease in visual acuity than patients with SI-30/40 silicone lenses, probably as a result of the difference in PCO rates between groups.