Photoacoustic generation for a spherical absorber with impedance mismatch with the surrounding media

J M Sun1, B S Gerstman

  • 1Physics Department, Florida International University, University Park, Miami, Florida 33199, USA.

Related Concept Videos

Shock Waves01:16

Shock Waves

While deriving the Doppler formula for the observed frequency of a sound wave, it is assumed that the speed of sound in the medium is greater than the source's speed through it. When this condition is breached, a shock wave occurs.
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high pressures...
Deriving the Speed of Sound in a Liquid01:09

Deriving the Speed of Sound in a Liquid

As with waves on a string, the speed of sound or a mechanical wave in a fluid depends on the fluid's elastic modulus and inertia. The two relevant physical quantities are the bulk modulus and the density of the material. Indeed, it turns out that the relationship between speed and the bulk modulus and density in fluids is the same as that between the speed and the Young's modulus and density in solids.
The speed of sound in fluids can be derived by considering a mechanical wave propagating...
Echo01:06

Echo

The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case, then the...
Atomic Absorption Spectroscopy: Radiation and Light Sources01:13

Atomic Absorption Spectroscopy: Radiation and Light Sources

Atomic absorption spectroscopy (AAS) relies on the Beer-Lambert law, which requires that the radiation source emits a narrow range of wavelengths to match the absorption characteristics of the analyte atom. The primary criteria for choosing an appropriate radiation source in AAS is to provide a precise and intense emission at specific wavelengths that will allow accurate detection of the analyte.
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...