Related Experiment Video
Updated: Oct 1, 2026

Use of Recombinant Fusion Proteins in a Fluorescent Protease Assay Platform and Their In-gel Renaturation
Published on: January 16, 2019
Design of new and sensitive fluorogenic substrates for human kallikrein hK3 (prostate-specific antigen) derived from
Sophie Réhault1, Michèle Brillard-Bourdet, Luc Bourgeois
1Laboratory of Enzymology and Protein Chemistry, INSERM EMI-U 00-10, University François Rabelais, 2bis Boulevard Tonnellé, 37032 Tours Cedex, France.
Abstract:
Human kallikrein hK3 (prostate-specific antigen) is a chymotrypsin-like serine protease which is widely used in the diagnosis of prostate cancer. Assays of the enzymatic activity of hK3 in extracellular fluids have been limited by a lack of sensitive synthetic substrates. This report describes the design of a series of internally quenched fluorescent peptides containing an amino acid sequence based on preferential hK3 cleavage sites in semenogelins. Those were identified by 2-D gel electrophoresis analysis and N-terminal sequencing of semenogelin fragments generated by ex vivo proteolysis in freshly ejaculated semen. These peptides were cleaved by hK3 at the C-terminal of certain tyrosyl or glutaminyl residues with k(cat)/K(m) values of 15000-60000 M(-1) s(-1). The substrate Abz-SSIYSQTEEQ-EDDnp was cleaved at the Tyr-Ser bond with a specificity constant k(cat)/K(m) of 60000 M(-1) s(-1), making it the best substrate for hK3 described to date.