Quantitative depth profiling of argon in tungsten films by secondary ion mass spectrometry
1Toshiba Corporation, Research and Development Center, Isogo, Yokohama, Japan.
Abstract:
Depth profiling of Ar in Ar-implanted tungsten (W) films with an excellent detection limit was investigated by secondary ion mass spectrometry (SIMS). Depth profiles of Ar with the detection of Ar+ and ArCs+ secondary ions, which were produced by O2+ and Cs+ primary ions, respectively, were compared in view of the detection limit and the depth resolution. The detection limit of Ar monitoring Ar+ was limited by the carbon- and oxygen-containing molecular ion (C2O+) in the sample as well as in the SIMS instrument. It was observed that some of the Ar+ ions were produced in the vacuum above the sample surfaces, whereas the ionization of almost all C2O+ occurred at the samples. By using different energy spectra between Ar+ and C2O+, we showed that the energy-filtering technique is advantageous for suppressing C2O+ ion detection. It is also confirmed that the ArCs+ secondary ion is only slighting by the C2OCs+ mass-interference ion. A detection limit of 4 x 10(18) cm(-3) for monitoring Ar+ and 3 x 10(16) cm(-3) for monitoring ArCs+ was achieved under a primary-ion current density of 0.16 mA/cm2. The detection of ArCs+ ion rather than Ar+ was found to be superior in the detection limit and the depth resolution. We conclude that SIMS is useful for the determination of the Ar depth distribution in W films.
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Atomic Emission Spectroscopy: Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
Atomic Fluorescence Spectroscopy