Experimental studies of pressure/temperature dependence of protein adsorption equilibrium in reversed-phase

P Szabelski1, A Cavazzini, K Kaczmarski

  • 1Department of Chemistry, The University of Tennessee, Knoxville 37996-1600, USA.

The effect of the average pressure and temperature of the column on the adsorption equilibrium of insulin variants on a C8 bonded silica was studied in isocratic reversed-phase HPLC. Analytical injections of samples of four different insulins (bovine, porcine. Lys-Pro and human recombinant) were carried out at constant flow-rate but under increased average pressure. The temperature dependence of the retention parameters over the range 25-50 degrees C was studied under two different average column pressures (47 and 147 bar). Substantial increases of the retention time (up to 300%) were observed when the pressure and/or the temperature were increased. Similar adsorption-induced changes in the partial molar volume at constant temperature (deltaVm approximately 102 ml/mol) were found for all the variants studied. Furthermore, deltaVm was revealed to be practically independent of the temperature, which suggests that the temperature has no or very little influence on the mechanism of the pressure induced perturbations in the molecular structure of the solute. This conclusion was also derived from the observed temperature dependence of the logarithm of the retention factor (k) measured under different pressures. The relation between the temperature and In k was nonlinear with a parabolic shape. Moreover, the shapes of the plots corresponding to the low and high pressures were found to be exactly the same, except that the curves were vertically shifted, due to the difference between the two average column pressures. These results indicate that pressure and temperature affect the retention behavior of insulins in a different and separate way.

Related Concept Videos

Chromatography: Introduction01:10

Chromatography: Introduction

Chromatography is a technique used to separate compounds based on differences of partitioning between two phases, the stationary phase and the mobile phase.
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Types Of Column Chromatography01:29

Types Of Column Chromatography

The stability and compatibility of column material with samples are crucial for efficient purification in chromatographic techniques. Various operating parameters such as pH, temperature, or solvent affect the packing of the column material, thereby determining the purification efficiency. The choice of column material also plays an essential role in deciding the operating parameters and can be modified based on the proteins that need to be purified.
Gel Filtration Chromatography
When the...
Analyte Adsorption and Distribution01:09

Analyte Adsorption and Distribution

In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and solvents...
Gas Chromatography: Types of Columns and Stationary Phases01:17

Gas Chromatography: Types of Columns and Stationary Phases

Gas chromatography (GC) relies on stationary phases to separate and analyze components in a sample. There are two main types of stationary phases: liquid and solid. Liquid stationary phases are non-volatile, thermally stable, and chemically inert liquids coated onto the column. Solid stationary phases are particles of adsorbent material, such as silica gel or molecular sieves.
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Introduction01:11

High-Performance Liquid Chromatography: Introduction

High-performance liquid chromatography(HPLC), formerly referred to as High-pressure liquid chromatography, is a powerful technique used to separate, identify, and quantify components in complex mixtures. The term "high pressure" refers to using high pressure to push the liquid mobile phase through the tightly packed columns.
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process01:05

High-Performance Liquid Chromatography: Elution Process

In High-Performance Liquid Chromatography (HPLC), the elution process is critical to the separation of analytes and the quality of chromatographic results. Elution describes how compounds move through the column and separate based on their interactions with the mobile and stationary phases. This process determines the resolution, peak shape, and retention times in the chromatogram, which are essential for identifying and quantifying components in complex mixtures. Understanding the elution...