Measuring the Carotid to Femoral Pulse Wave Velocity (Cf-PWV) to Evaluate Arterial Stiffness
Published on: May 3, 2018
[Epistemological focus on sphygmomanometry]
Rafael Chávez Domínguez1, Alfredo de Micheli
1Instituto Nacional de Cardiología Ignacio Chávez, México. rchavez@cardiologia.org.mx
Abstract:
In the XVIII century, the English naturalist Stephen Hales started to apply blood sphygmomanometry in animals. Direct recording of the blood pressure was first applied, in the XIX century, by AE Chauveau and JLM Poiseuille. However, it was not until 1856 that it was possible to perform a direct determination of blood pressure in humans by means of a device designed by Faivre. The first sphygmomanometer appeared at the end of the XIX century. The physician Samuel K. von Basch, native of Prague and who lived a few years in Mexico, fabricated successively three models of sphygmomanometers. The first (1881), with a mercury column, proved to be the most practical and useful. This instrument inspired the sphygmomanometer of the Italian physician Scipione Riva-Rocci who presented it in 1896. His sphygmomanometer, supported on the Vierordt principle, could measure manometrically the force needed to stop the pulse wave. Thanks to the research of Russian physician N. Korotkoff, the auscultatory method was added to sphygmomanometry. During the XX century other instruments to measure blood pressure were fabricated: the Pachon's and Plesch's oscillometers, as well as the aneroid manometer. On the other side, the use of direct tensional recordings has subsisted which has allowed to document the wide oscillations of arterial pressure levels during the day. Anyway, the sphygmomanometer with a mercury column has persisted until the present and will still be used for a long time. A new evolving methodology is the continuous ambulatory sphygmomanometry.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Errors occurring during blood pressure monitoring
Several factors...
Measurement of Blood Pressure