Related Experiment Video
Updated: Sep 13, 2026

Patient-specific Modeling of the Heart: Estimation of Ventricular Fiber Orientations
Published on: January 8, 2013
Simulation and prediction of cardiotherapeutical phenomena from a pulsatile model coupled to the Guyton circulatory
Jürgen Werner1, Daniel Böhringer, Martin Hexamer
1Department of Biomedical Engineering of the Medical Faculty, Ruhr-University, Bochum, Germany. werner@biomed.ruhr-uni-bochum.de
In order to use simulation prediction for cardiotherapeutical purposes, the well-documented and physiologically validated circulatory Guyton model was coupled to a cardiac pulsatile model which comprises the hemodynamics of the four chambers including valvular effects, as well as the Hill, Frank-Starling, Laplace, and autonomic nervous system (ANS) effects. The program is written in the "C" language and available for everybody. The program system was submitted to validation and plausibility tests both as to the steady-state and the dynamic properties. Pressures, volumes and flows and other variables turned out to be compatible with published experimental and clinical recordings both under physiological and pathophysiological conditions. The results from the application to cardiac electrotherapy emphasize the importance of atrial contraction to ventricular filling, the adequate atrio-ventricular delay, the effect of impaired ventricular relaxation, and the significance of the choice of the adequate cardiac pacemaker, both with respect to the stimulation site and the adequate sensor controlling pacing rate. The simulation will be further developed, tested and applied for cardiological purposes.
In order to use simulation prediction for cardiotherapeutical purposes, the well-documented and physiologically validated circulatory Guyton model was coupled to a cardiac pulsatile model which comprises the hemodynamics of the four chambers including valvular effects, as well as the Hill, Frank-Starling, Laplace, and autonomic nervous system (ANS) effects. The program is written in the "C" language and available for everybody. The program system was submitted to validation and plausibility tests both as to the steady-state and the dynamic properties. Pressures, volumes and flows and other variables turned out to be compatible with published experimental and clinical recordings both under physiological and pathophysiological conditions. The results from the application to cardiac electrotherapy emphasize the importance of atrial contraction to ventricular filling, the adequate atrio-ventricular delay, the effect of impaired ventricular relaxation, and the significance of the choice of the adequate cardiac pacemaker, both with respect to the stimulation site and the adequate sensor controlling pacing rate. The simulation will be further developed, tested and applied for cardiological purposes.
Related Concept Videos
Pathophysiology of Cardiac Performance
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Autoregulation of Blood Flow
Chemical Signaling in Autoregulation
Chemical signaling operates at the precapillary sphincter level, inciting either contraction or relaxation.
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...