Related Experiment Videos
Measurement of endogenous carbon monoxide formation in biological systems
Gerald S Marks1, Hendrik J Vreman, Brian E McLaughlin
1Department of Pharmacology and Toxicology, Queen's University, Kingston, Ontario, Canada, K7L 3N6. gsm@post.queensu.ca
Abstract:
Endogenous carbon monoxide (CO) formation has been measured in different biological systems using a variety of analytical procedures. The methods include gas chromatography-reduction gas detection, gas chromatography-mass spectroscopic detection, laser sensor-infrared absorption, UV-visible spectrophotometric measurement of CO-hemoglobin or CO-myoglobin complex, and formation of (14)CO from (14)C-heme formed following [2-(14)C]glycine administration. CO formation ranged from a low of 0.029 nmol/mg of protein/h in chorionic villi of term human placenta to a high of 0.28 nmol/mg of protein/h in rat olfactory receptor neurons in culture and rat liver perfusate.