Related Experiment Video
Updated: Aug 19, 2026

Determining the Contribution of the Energy Systems During Exercise
Published on: March 20, 2012
Calculation is unsuitable for determination of O2-consumption (VO2) in case of O2-supply-dependency
G I Kemming1, F G Meisner, M Kleen
1Institute for Surgical Research and Clinic of Anesthesiology, Klinikum Grosshadem, Ludwig-Maximilians-University Munich, Germany. gregor.kemming@icf.med.uni-muenchen.de
Background:
When O2-delivery to tissues is critically reduced, O2-consumption becomes dependent on O2-delivery and starts to decline, which reflects tissue hypoxia. In order to timely detect tissue hypoxia prior to organ damage, O2-consumption may be calculated or measured from respiratory gases. We have assessed reproducibility of calculated and measured O2-consumption-data and their agreement during O2-supply-dependency.
Method:
Data of 31 anesthetized, ventilated pigs were analysed retrospectively. Animals had undergone either controlled hemorrhage ("shock") or isovolemic exchange of blood with colloids (extreme hemodilution, "HD") until O2-consumption had become dependent on O2-delivery. O2-consumption was calculated from the Fick equation and measured simultaneously with a DELTATRAC II metabolic monitor. Repeatability was determined for (1) calculated and (2) for measured.VO2 -values and (3) for input variables of the Fick equation (i.e. cardiac index (CI) and arteriovenous O2-content difference (CaO2-CvO2)). Bias between calculated and measured data and precision of calculation were assessed from paired O2-consumption-values obtained before and after induction of O2-supply-dependency via hemorrhage or extreme hemodilution.
Results:
Repeatability of the reversed Fick method was inferior to repeatability of measurement (27 vs 15%) due to error propagation from CI and (CaO2-CvO2). Between-method-bias at baseline ("BL") was 3%, and changed in case of O2-supply-dependency (shock -15%; HD -31%, both p<0.05 vs BL), precision of the reversed Fick method deteriorated (BL 32%; shock 60%; HD 60%) due to variability of CI (CV: 16%; shock 27%; HD 41%).
Conclusion:
In anesthetized pigs calculated and measured O2-consumption values are in agreement, while in presence of O2-supply-dependency the reversed Fick method (1) grossly underestimates true O2-consumption and (2) precision deteriorates not allowing to verify or reject the presence of tissue hypoxia.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Oxygen Transport in the Blood