Related Experiment Video
Updated: Aug 6, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Development of comparative methods using gas chromatography-mass spectrometry and capillary electrophoresis for
1Department of Applied Science, Limerick Institute of Technology, Ireland. fiona.regan@lit.ie
Abstract:
Two analytical separation techniques are being investigated for their potential in determining a wide range of endocrine disrupting chemicals (EDCs) in the environment. Capillary electrophoresis (CE) in the micellar mode in conjunction with a cyclodextrin (CD) modifier is shown to have potential for determination of alkylphenol breakdown products. Gas chromatography with mass spectrometric (GC-MS) detection is being utilised for validation of the CE method development and in addition as a separation technique to optimise preconcentration using solid-phase extraction. GC has demonstrated potential for the separation of 26 priority chemicals suspected as being endocrine disrupting compounds. The challenge of the method development process lies in the fact that these compounds are of differing polarities, size and charge and therefore are difficult to separate in a single run. Capillary electrophoresis in the CD-MEKC (micellar electrokinetic chromatography) mode is showing potential in this regard. Limits of determination are in the low mg/l range for CE and GC, however, using preconcentration it is possible to improve detection sensitivity with >80% recovery for some analytes and up to 100% recovery for most target species.
More Related Videos
08:00Screening for Endocrine Activity in Water Using Commercially-available In Vitro Transactivation Bioassays
Published on: December 4, 2016
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...