Improving the use of mixing factors for dilution ventilation design
Charles E Feigley1, James S Bennett, E Lee
1Department of Environmental Health Sciences, School of Public Health, University of South Carolina, Columbia, USA.
Abstract:
In specifying dilution ventilation flow rate, a safety factor, K, is often used to provide a margin of safety and to compensate for uncertainties and health impact severity. In current practice, the selection of K is very subjective. Here the component of K accounting for imperfect mixing, Km, was studied to develop more effective and efficient design procedures. Air flow and contaminant distribution in a 10 m x 3 m x 7 m room with a single contaminant source on a 1-m high table were simulated for steady, isothermal conditions using computational fluid dynamics. A series of 10 simulations explored factorial combinations of air exchange rates (1, 2,4, 8, 16 ACH) and inlet types (a high wall jet and a ceiling diffuser). Nine additional simulations explored exhaust opening location effects and 13 other simulations investigated source location effects. Km was calculated at each of 25,600 grid locations within the room by linear regression of emission rate/flow rate (G/Q) on concentration (C). The linear relationship between C and G/Q at each of the points was nearly perfect (R2 > 0.97). For the simulations with varying dilution flow rate, Km ranged from 0.19 to 2.86 for the wall jet and from 0.94 to 4.34 for the ceiling diffuser. Holding G/Q at 100 ppm and varying source and exhaust location produced room average concentrations from 55.7 to 173 ppm. Unlike orthodox design approaches, this work suggests that air monitoring data often can be used to calculate dilution flow rate requirements. Also, dilution flow rate requirements may be reduced by enhancing room mixing with fans or altering air inlet configuration. However, mixing should not be increased if the altered room air currents could transport contaminant to an occupant's breathing zone or interfere with other control methods that depend on segregation of incoming air and contaminant.
Related Concept Videos
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Mechanical Ventilation I: Indication and Settings
Mixing Time
Bioreactor Controls-II