Related Experiment Video
Updated: May 6, 2026

Percutaneous Contrast Echocardiography-guided Intramyocardial Injection and Cell Delivery in a Large Preclinical Model
Published on: January 21, 2018
Electrical conduction in canine pulmonary veins: electrophysiological and anatomic correlation
Mélèze Hocini1, Siew Y Ho, Tokuhiro Kawara
1Hôpital Cardiologique du Haut-Lévèque, Pessac, France.
Background:
Paroxysmal atrial fibrillation in patients is often initiated by foci in the pulmonary veins. The mechanism of these initiating arrhythmias is unknown. The aim of this study was to determine electrophysiological characteristics of canine pulmonary veins that may predispose to initiating arrhythmias.
Methods And Results:
Extracellular recordings were obtained from the luminal side of 9 pulmonary veins in 6 Langendorff-perfused dog hearts after the veins were incised from the severed end to the ostium. Pulmonary veins were paced at the distal end, the ostium, and an intermediate site. During basic and premature stimulation, extracellular electrical activity was recorded with a grid electrode that harbored 247 electrode terminals. In 4 hearts, intracellular electrograms were recorded with microelectrodes. Myocyte arrangement immediately beneath the venous walls was determined by histological analysis in 3 hearts. Extracellular mapping revealed slow and complex conduction in all pulmonary veins. Activation delay after premature stimulation could be as long as 96 ms over a distance of 3 mm. Action potential duration was shorter at the distal end of the veins than at the orifice. No evidence for automaticity or triggered activity was found. Histological investigation revealed complex arrangements of myocardial fibers that often showed abrupt changes in fiber direction and short fibers arranged in mixed direction.
Conclusions:
Zones of activation delay were observed in canine pulmonary veins and correlated with abrupt changes in fascicle orientation. This architecture of muscular sleeves in the pulmonary veins may facilitate reentry and arrhythmias associated with ectopic activity.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Pulmonary Hypertension: Classification and Pathogenesis
There are various classifications for PH, each relating to different underlying causes and also...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...

