Doppler Ultrasound-Based Leg Blood Flow Assessment During Single-Leg Knee-Extensor Exercise in an Uncontrolled Setting
Published on: December 15, 2023
A simple water-filled plethysmograph for measurement of limb blood flow in humans
Neil M Raine1, Jennifer C Sneddon
1School of Biological and Earth Sciences, Liverpool John Moores University, Liverpool L3 3AF, United Kingdom. N.Raine@livjm.ac.uk
Abstract:
Fundamental principles underpinning the study of cardiovascular physiology can be emphasized by measuring blood flow. Plethysmography is an appropriate, noninvasive technique to use but may not be available to some institutions. Therefore, for measurement of blood flow in human limbs, we developed a simple water-filled plethysmograph that may be built with minimal technical support. The device is formed from a plastic cylinder and houses a latex sleeve sealed at either end by means of circular flanges and rubber O-ring seals. Limb volume changes are transcribed using an air-filled piston recorder. This instrument proves to be sensitive and accurately determines limb volume changes over time. Utilizing an appropriate venous occlusion protocol, predicted vascular responses to postural challenge and physical exercise may be followed. In response to a questionnaire, a majority of students (n = 33) agreed that performing blood flow measurements succeeded in relating theory to practice, improved technical and observational skills, and made the learning experience real. This modified plethysmograph proves to be a valuable teaching tool in human physiology classes.
Related Concept Videos
Assessing Blood pressure in the Leg
Preparation:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Blood Flow
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Measurement of Blood Pressure