Transantral endoscopic orbital floor repair using resorbable plate.
Barbara L Persons1, Granger B Wong
1Division of Plastic Surgery, University of California, Davis Medical Center, Sacramento 95817, USA.
The Journal of Craniofacial Surgery
|June 1, 2002
Summary
This study presents a transantral endoscopic approach for orbital floor blowout fractures, avoiding eyelid incisions. This method utilizes a bone flap and endoscope for precise repair with resorbable plates, enhancing patient outcomes.
Area of Science:
- Ophthalmology
- Oral and Maxillofacial Surgery
- Neurosurgery
Background:
- Orbital floor blowout fractures are common facial injuries.
- Traditional surgical approaches often involve lower eyelid incisions, carrying risks of scarring and ectropion.
- Minimally invasive techniques are sought to improve patient outcomes and reduce complications.
Purpose of the Study:
- To evaluate the efficacy and safety of a transantral endoscopic approach for repairing pure orbital floor blowout fractures.
- To demonstrate a technique that avoids external lower eyelid incisions.
Main Methods:
- A transoral incision provides access to the anterior maxillary wall.
- A 1-cm² antral bone flap allows entry into the maxillary sinus and access to the orbital floor.
- A 30-degree, 4-mm endoscope is used for visualization and fracture assessment.
- Resorbable bone plating material is sized, inserted, and positioned on stable bony shelves within the orbital defect.
Main Results:
- The transantral endoscopic approach successfully repaired pure orbital floor blowout fractures.
- This technique avoids the need for lower eyelid incisions.
- Resorbable bone plates were effectively utilized, with screw fixation only required in cases of inadequate bony shelf stability.
Conclusions:
- The transantral endoscopic orbital floor approach is a viable and effective alternative for treating pure orbital floor blowout fractures.
- This minimally invasive technique reduces the risks associated with traditional lower eyelid incisions.
- The use of resorbable plating offers stable reconstruction with potential for screw fixation if necessary.