Unconstrained and non-invasive measurement of heart-beat and respiration periods using a phonocardiographic sensor
S Tanaka1, Y Matsumoto, K Wakimoto
1Faculty of Engineering, Yamaguchi University, Japan.
Abstract:
With the rapid growth in the number of elderly people in the population, interest in health monitoring is increasing. Therefore the development of an unconstrained and non-invasive vital signs measurement system could be important for monitoring health status at home or in hospitals or nursing facilities. A simple system is proposed for measuring heart-beat and respiration periods for home healthcare. This was achieved with a phonocardiographic (PCG) sensor set on a water-mat or air-mat. The PCG sensor was an acceleration sensor that extracted the vibration of the mat caused by heart-beat and respiration. By calculating an autocorrelation function of the fully rectified sensor output or by local pattern matching between the rectified output and a reference signal (pre-memorised for each subject), the system measured the average and instantaneous periods of both heart-beat and respiration. Results showed that these periods were measured to a similar level of accuracy as for the electrocardiogram and thermistor respiration pickup. The comparative accuracies were within the following ranges: average heartbeat 0.19% to 0.67%, instantaneous heartbeat 0.53% to 1.15%, average respiration 0.51% to 2.17%, and instantaneous respiration 2.51% to 5.20%.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac muscle...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Holter Monitor: 24-Hour Monitoring
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for: