Related Experiment Video
Updated: Oct 1, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
The effects of dynamization and destabilization of the external fixator on fracture healing: a comparative
Mehmet Arazi1, Hakan Yalcin, Necmettin Tarakcioglu
1Department of Orthopedics and Traumatology, School of Medicine, Selçuk University, Konya, Turkey.
Abstract:
This study compared the effects of axial dynamization and staged destabilization on fracture healing. Bilateral midshafts of canine tibiae were osteotomized and fixed with an external fixator. The hind limbs were divided into two groups: the destabilized group in which the fixator's stiffness was progressively reduced over time and the axially dynamized group in which the fixator was axially dynamized. The healed tibiae were tested for 3-point bending in the anteroposterior plane. The biomechanical tests performed 2 months postoperatively revealed that the side with the destabilized fixator was more rigid than the side with the axially dynamized fixator, but the differences were insignificant (P=.20). This study showed staged destabilization of the fixator's stiffness was as effective on the enhancement of fracture healing as axial dynamization.
More Related Videos
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
06:41A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018