Is it open or is it closed? Thrombosis of a St. Jude's tricuspid valve prosthesis
Divya Mehra1, Paul A Tunick, Gregory M Goodkin
1Noninvasive Cardiology Laboratory, NYU School of Medicine, New York, NY 10016, USA.
A 49-year-old woman with mitral and tricuspid mechanical valve prostheses developed marked weight gain with increasing abdominal girth and facial plethora 4 weeks after anticoagulation was temporarily interrupted for abdominal surgery. Transthoracic and transesophageal echocardiography documented severe tricuspid stenosis and regurgitation. The two discs of the tricuspid prosthesis were immobilized, half open and half closed. The prosthesis was replaced and the patient did well.
A 49-year-old woman with mitral and tricuspid mechanical valve prostheses developed marked weight gain with increasing abdominal girth and facial plethora 4 weeks after anticoagulation was temporarily interrupted for abdominal surgery. Transthoracic and transesophageal echocardiography documented severe tricuspid stenosis and regurgitation. The two discs of the tricuspid prosthesis were immobilized, half open and half closed. The prosthesis was replaced and the patient did well.