High-speed gas chromatographic analysis of solvents in pharmaceuticals using solid phase microextraction
Related Experiment Video
Updated: Sep 30, 2026

Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
1Pharmacia Corporation, Global Chemical Process R&D, 4901 Searle Parkway, Skokie, IL 60077, USA. anil.r.raghani@pharmacia.com
Abstract:
A simple, inexpensive and rapid analytical approach for the determination of organic volatile impurities in pharmaceutical drug substances is developed, where sample preparation step was conducted using solid phase microextraction (SPME), followed by a fast GC separation. With an extraction time between 3 and 5 min and separation of 13 solvents in less than 3 min employing fast temperature programming using resistively heated column, organic volatile impurities can be analyzed within a total analysis time of 6-9 min. Various SPME phases were evaluated towards sensitivity and selectivity for the extraction of 13 commonly found solvents in drug substances dissolved in dimethyl sulfoxide and water. A 2-cm Carboxen/polydimethyl siloxane/divinylbenzene (Carboxen/PDMS/DVB) phase and a 65-microm DVB/PDMS phase showed better sensitivity towards these solvents when extracted from organic and aqueous matrix in comparison with the sensitivity obtained with direct injection approach. Extraction parameters such as extraction time, extraction stir rate, etc. are discussed. %RSD of peak area of replicate extraction was between 2 and 10% when 100 microm PDMS was used for extracting solvents from aqueous matrix. When DVB/PDMS fiber was evaluated for precision, %RSD of peak area from replicate extractions of solvents from organic matrix was between 2 and 8%. One-hundred micrometer PDMS showed excellent linearity from 10 to 500 microg/ml for analytes extracted from water solutions. On the other hand, DVB/PDMS phase showed better linearity than Carboxen/PDMS/DVB fiber when it was used to extract analytes in the concentration range of 10-5000 microg/ml from organic matrix.
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
High-Performance Liquid Chromatography: Elution Process
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Instrumentation