Can a clinically useful aortic pressure wave be derived from a radial pressure wave?
S Söderström1, G Nyberg, M F O'Rourke
1Department of Anaesthesia and Intensive Care, Sahlgrenska University Hospital, Göteborg, Sweden.
Background:
The information contained in arterial pressure waveforms is probably underused by most clinicians who manage critically ill patients. It is not generally known that an aortic pressure wave can be synthesized by applying a generalized transfer function to the radial arterial pressure wave. We validated a commercially available system, SphygmoCo (PWV Medical, Sydney).
Methods:
Ascending aortic pressure waves were synthesized and comparisons were made between the synthesized aortic waveforms, the measured aortic and radial arterial waveforms. Ascending aortic pressure waves (catheter-tip manometer) and radial artery pressure waves (short fluid-filled catheter) were recorded simultaneously in 12 patients with angina pectoris (age 62-76 years) undergoing cardiac catheterization. Patients were studied at rest, following midazolam, sublingual nitroglycerin and during Valsalva manoeuvres.
Results:
Both midazolam and nitroglycerin lowered mean arterial pressure but nitroglycerin caused a more selective decrease in the measured and synthesized aortic systolic pressures than in the radial artery pressure. The synthesized aortic systolic pressure was less, by 6-8 mm Hg (SD 2-3) and the synthesized aortic diastolic pressure greater, by 4 mm Hg (SD 2). Despite these differences in pulse pressure, the synthesized waveform tracked the measured waveform before and during interventions.
Conclusions:
By deriving an aortic waveform from the radial pulse, monitoring of left ventricular afterload can improve without more invasive means.
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical indicator...