Improved lung delivery from a passive dry powder inhaler using an Engineered PulmoSphere powder
Sarma P Duddu1, Steven A Sisk, Yulia H Walter
1Inhale Therapeutic Systems Inc., San Carlos, California 94070, USA.
Purpose:
To assess the pulmonary deposition and pharmacokinetics of an engineered PulmoSphere powder relative to standard micronized drug when delivered from passive dry powder inhalers (DPIs).
Methods:
Budesonide PulmoSphere (PSbud) powder was manufactured using an emulsion-based spray-drying process. Eight healthy subjects completed 3 treatments in crossover fashion: 370 microg budesonide PulmoSphere inhaled from Eclipse DPI at target PIF of 25 L x min(-1) (PSbud25), and 50 L x min(-1) (PSbud50), and 800 microg of pelletized budesonide from Pulmicort Turbuhaler at 60 L x min(-1)(THbud60). PSbud powder was radiolabeled with 99mTc and lung deposition determined scintigraphically. Plasma budesonide concentrations were measured for 12 h after inhalation.
Results:
Pulmonary deposition (mean +/- sd) of PSbud was 57+/-7% and 58+/-8% of the nominal dose at 25 and 50 L x min(-1), respectively. Mean peak plasma budesonide levels were 4.7 (PSbud25), 4.0 (PSbud50), and 2.2 ng x ml(-1) (THbud60). Median t(max) was 5 min after both PSbud inhalations compared to 20 min for Turbuhaler (P < 0.05). Mean AUCs were comparable after all inhalations, 5.1 (PSbud25), 5.9 (PSbud50), and 6.0 (THbud60) ng x h x ml(-1). The engineered PSbud powder delivered at both flow rates from the Eclipse DPI was twice as efficiently deposited as pelletized budesonide delivered at 60 L x min(-1) from the Turbuhaler. Intersubject variability was also dramatically decreased for PSbud relative to THbud.
Conclusion:
Delivery of an engineered PulmoSphere formulation is more efficient and reproducible than delivery of micronized drug from passive DPIs.
Related Concept Videos
Breathing
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Pulmonary Cycle: Exhalation
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Inhaled Medications