Application of isotopically labeled methylmercury for isotope dilution analysis of biological samples using gas
R C Rodriguez Martín-Doimeadios1, E Krupp, D Amouroux
1Laboratoire de Chimie Analytique Bio-Inorganique et Environnement, CNRS UMR 5034, Université de Pau et des Pays de l'Adour, Hélioparc, France.
Abstract:
An isotope dilution (ID) procedure for the determination of methylmercury (MMHg) in biological samples using an inductively coupled plasma mass spectrometer as detector after the capillary gas chromatographic separation (CGC/ICPMS) has been developed. For the first time, open-focused-microwave pretreatment has been used in conjunction with ID. Optimum conditions for the measurement of isotope ratios on the fast transient chromatographic peaks have been established. Mass bias was found to be about 1.5%/mass unit and was corrected by using the simultaneously measured thallium signals at 203Tl and 205Tl. After mass-bias correction, deviation of the theoretical mercury ratio values was found to be as low as 0.2%. Isotope ratio precisions based on the peak areas measurements were 0.3% RSD for 20 pg injected (as Hg absolute). The absolute detection limits were in the range of 20-30 fg for 202Hg and 201Hg. Methylmercury enriched in 201Hg has been synthesized by direct reaction with methylcobalamine. The concentration of the MMHg spike has been measured by reverse isotope dilution with a natural MMHg standard. The capabilities of CGC/ICPMS to measure isotope ratios were used to optimize sample derivatization by aqueous ethylation with NaBEt4 with respect to MMHg degradation pathways and quantitative recovery. The accuracy of the method developed has been validated with biological certified reference materials (CRM-463, DORM-1).
More Related Videos
12:59A Study of the Complexation of Mercury(II) with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
11:18A Practical Guide on Coupling a Scanning Mobility Sizer and Inductively Coupled Plasma Mass Spectrometer (SMPS-ICPMS)
Published on: July 11, 2017
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...