Related Experiment Video
Updated: Jul 29, 2026

Characterization of Metabolic Status in Nonhuman Primates with the Intravenous Glucose Tolerance Test
Published on: November 13, 2016
Serum fructosamine concentration in nondiabetic and diabetic cats
Michelle L. Plier1, Carol B. Grindem, Peter S. MacWilliams
1Department of Microbiology, Parasitology, and Pathology, College of Veterinary Medicine, North Carolina State University, Raleigh, NC 27606, USA.
Abstract:
Differentiating transient hyperglycemia from diabetic hyperglycemia can be difficult in cats since single blood glucose measurements reflect only momentary glucose concentrations, and values may be elevated because of stress-induced hyperglycemia. Glycated protein measurements serve as monitors of longer-term glycemic control in human diabetics. Using an automated nitroblue tetrazolium assay, fructosamine concentration was measured in serum from 24 healthy control cats and 3 groups of hospitalized cats: 32 euglycemic, 19 transiently hyperglycemic, and 12 diabetic cats. Fructosamine concentrations ranged from 2.1 - 3.8 mmol/L in clinically healthy cats; 1.1 - 3.5 mmol/L in euglycemic cats; 2.0 - 4.1 mmol/L in transiently hyperglycemic cats; and 3.4 to >6.0 mmol/L in diabetic cats. Values for with-in-run precision at 2 fructosamine concentrations (2.64 mmol/L and 6.13 mmol/L) were 1.5% and 1.3%, respectively. Between-run coefficient of variation was 3.8% at a fructosamine concentration of 1.85 mmol/L. The mean fructosamine concentration for the diabetic group differed significantly (P=0.0001) from the mean concentrations of the other 3 groups. Poorly regulated or newly diagnosed diabetic cats tended to have the highest fructosamine values, whereas well-regulated or over-regulated diabetic cats had values approaching the reference range. As a single test for differentiating nondiabetic cats from diabetic cats, fructosamine was very sensitive (92%) and specific (96%), with a positive predictive value of 85% and a negative predictive value of 98%. Serum fructosamine concentration shows promise as an inexpensive, adjunct diagnostic tool for differentiating transiently hyperglycemic cats from poorly controlled diabetic cats.
More Related Videos
08:13Study of In Vivo Glucose Metabolism in High-fat Diet-fed Mice Using Oral Glucose Tolerance Test (OGTT) and Insulin Tolerance Test (ITT)
Published on: January 7, 2018
10:35Extracellular Glucose Depletion as an Indirect Measure of Glucose Uptake in Cells and Tissues Ex Vivo
Published on: April 6, 2022
Related Concept Videos
Serum Studies: Renal Function Tests
Type II Diabetes Mellitus III: Clinical Manifestations and Diagnosis