Variability in infusion pressure and continuous flow rate delivered from pressurized bag pump flush systems
Related Experiment Video
Updated: Sep 30, 2026

Pneumococcus Infection of Primary Human Endothelial Cells in Constant Flow
Published on: October 31, 2019
M I Hug1, V Buettiker, A Cornelius
1Department of Anaesthesia, University Children's Hospital Zurich, Switzerland.
Abstract:
Using 10 different infusion bag pressure pumps, indicated manometer pressures were compared with measured infusion pressures proximal to the flow-regulating device in an in vitro experiment. Flow rates delivered through the flow-regulating device were gravimetrically measured at different monitored pressure levels. Significant differences were found between manometer and measured infusion pressures among the tested pressure bagpumps (e.g. 500 ml bag volumepressurized to 300 mmHg manometerpressure: 219.6 +/- 7.8 to 407.2 +/- 2.7 mmHg). The infusion pressures were additionally affected by the vertical level of the infusion bag pump and by the volume of the infusion bag. Flow rates delivered through the flow-regulating device were directly correlated to the measured infusion pressure (r2= 0.9926). Differences inflow rates can have a considerable impact on maintaining catheter patency and avoidance of fluid overload and retrograde flushing into the central arterial circulation in neonates and small children. A simple manoeuvre using the invasive pressure transducer allows monitoring and adjustment of the infusion pressure in the clinical setting.
Related Concept Videos
Drug Accumulation During Multiple Dosing: Intermittent IV Infusions
One-Compartment Model: IV Infusion
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Fluid Pressure
According to Pascal's law, a fluid at rest will generate equal pressure in all directions. This pressure is measured as a force per unit area, and its magnitude depends on the fluid's specific weight or...
Bioreactor Controls-I
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Bernoulli's Principle: Applications
Entrainment devices use a high fluid speed to create low pressures and, thus, entrain one fluid into another. Some examples of these devices are given below: