Related Experiment Video
Updated: Jul 22, 2026

Voluntary Breath-hold Technique for Reducing Heart Dose in Left Breast Radiotherapy
Published on: July 3, 2014
Patient effective radiation dose and associated risk from transmission scans using 153Gd line sources in cardiac
Kostas Perisinakis1, Nicholas Theocharopoulos, Nicholas Karkavitsas
1Department of Medical Physics, Faculty of Medicine, University of Crete, Iraklion, Greece. perisina@med.uoc.gr
Abstract:
The aim of the present study was to determine the contribution of transmission measurements acquisition to total patient effective dose from cardiac SPECT studies. A dual-head L-shaped gamma camera equipped with a transmission scan acquisition system based on two 153Gd line sources was used to simulate transmission measurements acquisition exposure on an anthropomorphic phantom. Thermoluminescence dosimeters were used to directly monitor the dose to 550 measuring points in the phantom. The effective dose and associated risk from transmission scans acquisition were estimated and compared to those associated to the radiopharmaceutical injected. The maximum effective dose from a typical transmission measurements acquisition was 1.3 microSv and 1.9 microSv for male and female patients, respectively. The contribution of the typical transmission scans acquisition to total patient radiation risk from a cardiac SPECT study is less than 10(-3). Thus, radiation exposure may not be considered as a limiting factor for the clinical application of attenuation correction methods based on transmission measurements in cardiac SPECT.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
08:36Multi-Tracer Studies of Brain Oxygen and Glucose Metabolism Using a Time-of-Flight Positron Emission Tomography-Computed Tomography Scanner
Published on: June 7, 2024
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT