Effects of meteorological conditions on aerosol composition and mixing state in Bakersfield, CA

Jeffrey R Whiteaker1, David T Suess, Kimberly A Prather

  • 1Department of Chemistry, University of California, Riverside 92521, USA.

Related Concept Videos

Atomic Spectroscopy: Effects of Temperature01:27

Atomic Spectroscopy: Effects of Temperature

Atomization, converting samples into gas-phase atoms and ions, is essential for atomic spectroscopy. The flame temperature required for atomization affects the efficiency of the atomic spectroscopic methods by increasing the atomization efficiency and the relative population of the excited and ground states.
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
The Colloidal State01:29

The Colloidal State

The formation of a colloidal system is exemplified by an aqueous solution containing Cl− ions is introduced to another containing Ag+ ions, resulting in the precipitation of solid AgCl as extremely tiny crystals. Instead of settling out as a filterable precipitate, these crystals remain suspended in the liquid, showcasing a colloidal system.A colloidal system involves colloidal particles within the approximate range of 1 to 1000 nm in at least one dimension, dispersed in a medium called the...
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Microbes and Climate Change01:27

Microbes and Climate Change

Microorganisms are pivotal agents in Earth's biogeochemical cycles, significantly influencing climate dynamics through their metabolic activities. These microbes modulate the levels of key greenhouse gases by both contributing to and helping mitigate climate change.Microbial Contributions to Greenhouse Gas EmissionsRising global temperatures accelerate microbial metabolism, which, in turn, speeds up the decomposition of organic matter. This process releases carbon dioxide (CO₂) through...