Related Experiment Video
Updated: Aug 19, 2026

A Minimally Invasive Model to Analyze Endochondral Fracture Healing in Mice Under Standardized Biomechanical Conditions
Published on: March 22, 2018
A comparison of bicortical and intramedullary screw fixations of Jones' fractures
Zeeshan S Husain1, Donna J DeFronzo
1Department of Medicine and Surgery, Dr. William M. Scholl College of Podiatric Medicine, Chicago, IL 60610, USA.
Abstract:
Two different fixations for treatment of Jones' fracture were tested in bone models and cadaveric specimens to determine the differences in the stability of the constructs. A bicortical 3.5-mm cannulated cortical screw and an intramedullary 4.0-mm partially threaded cancellous screw were tested using physiologic loads with an Instron 8500 servohydraulic tensiometer (Instron Corporation, Canton, MA). In bone models, the bicortical construct (n = 5, 87+/-23 N) showed superior fixation strength (p = .0009) when compared to the intramedullary screw fixation (n = 5, 25+/-13 N). Cadaveric testing showed similar statistical significance (p = .0124) with the bicortical construct (n = 5, 152+/-71 N) having greater load resistance than the intramedullary screw fixation (n = 4, 29+/-20 N). In bone models, the bicortical constructs (23+/-9 N/mm) showed over twice the elastic modulus than the intramedullary screw fixations (9+/-4 N/mm) with statistical significance (p = .0115). The elastic modulus in the cadaveric group showed a similar pattern between the bicortical (19+/-17 N/mm) and intramedullary (9+/-6 N/mm) screw constructs. Analysis of the bicortical screw failure patterns revealed that screw orientation had a critical impact on fixation stability. The more distal the exit site of the bicortical screw was from the fracture site, the greater the load needed to displace the fixation.
More Related Videos
04:41Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical bending,...