Jove
Visualize
Contact Us

Related Experiment Videos

Using flow injection analysis to time-resolve rhythmic and pulsatile signals.

R Alan Wheatley1

  • 1Department of Chemistry, University of Hull, UK. rawheatley@canadalane.demon.co.uk

The Analyst
|June 26, 2002
PubMed
Summary
This summary is machine-generated.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Flow injection chemiluminescence determination of cefadroxil using potassium permanganate and formaldehyde system.

Journal of pharmaceutical and biomedical analysis·2006
Same author

Ultrasound-enhanced flow injection chemiluminescence for determination of hydrogen peroxide.

The Analyst·2006
See all related articles
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Continuous monitoring detects biological rhythms, but dispersion broadens concentration peaks, obscuring high-frequency signals. Flow injection techniques were found to resolve these overlapping peaks, enabling clearer rhythm detection.

Area of Science:

  • Analytical Chemistry
  • Biophysics
  • Biotechnology

Background:

  • Continuous monitoring is crucial for detecting biological rhythms.
  • Dispersion in monitoring systems broadens concentration peaks, obscuring high-frequency chemoperiodicities.
  • Overlapping peaks hinder the accurate observation of rapid biological oscillations.

Purpose of the Study:

  • To investigate the utility of flow injection for resolving overlapping concentration peaks in continuous monitoring.
  • To determine if flow injection can restore the observability of high-frequency biological rhythms affected by dispersion.
  • To propose a design for an automated instrument based on these findings.

Main Methods:

  • Spectrophotometric measurement of a rhythmically varying permanganate concentration.

Related Experiment Videos

  • Experimental manipulation of dispersion coefficients (3.0 and 3.9).
  • Utilizing a flow injection system with an injection valve to subsample the stream.
  • Main Results:

    • A rhythm (0.08 Hz) was observable at a dispersion coefficient of 3.0 but not at 3.9.
    • High dispersion obscured the rhythm, resulting in a single recorded peak.
    • Flow injection, applied after a high dispersion manifold, restored the rhythm's observability.

    Conclusions:

    • Flow injection is an effective method for resolving overlapping concentration peaks caused by dispersion.
    • This technique can improve the detection of high-frequency chemoperiodicities in continuous monitoring.
    • The study proposes a design for an automated instrument to output time-series concentration data.