Related Experiment Video
Updated: May 26, 2026

Cardiac Stress Test Induced by Dobutamine and Monitored by Cardiac Catheterization in Mice
Published on: February 10, 2013
Coronary pressure measurement after stenting predicts adverse events at follow-up: a multicenter registry
Nico H J Pijls1, Volker Klauss, Uwe Siebert
1Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands. cardiologie.catharina.zks@wxs.nl
Background:
Coronary stenting is associated with a restenosis rate of 15% to 20% at 6-month follow-up, despite optimum angiographic stent implantation. In this multicenter registry, we investigated the relation between optimum physiological stent implantation as assessed by poststent fractional flow reserve (FFR) and outcome at 6 months.
Methods And Results:
In 750 patients, coronary pressure measurement at maximum hyperemia was performed after angiographically apparently satisfactory stent implantation. Poststenting FFR was calculated and related to major adverse events (including need for repeat target vessel revascularization) at 6 months. In 76 patients (10.2%), at least 1 adverse event occurred. Five patients died, 19 experienced myocardial infarction, and 52 underwent at least 1 repeat target vessel revascularization. By multivariate analysis, FFR immediately after stenting was the most significant independent variable related to all types of events. In 36% of the patients, FFR normalized (>0.95), and event rate was 4.9% in that group. In 32% of the patients, poststent FFR was between 0.90 and 0.95, and event rate was 6.2%. In 32% of patients, poststent FFR was <0.90, and event rate was 20.3%. In 6% of the patients, FFR was <0.80, and event rate was 29.5% (P<0.001).
Conclusions:
FFR after stenting is a strong independent predictor of outcome at 6 months.
More Related Videos
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure