Related Experiment Video
Updated: Aug 19, 2026

Programmed Electrical Stimulation in Mice
Published on: May 26, 2010
Multiple spatially distributed stimulators and timing programs for entrainment of activation during ventricular
Yiping Gu1, Abhijit Patwardhan
1Center for Biomedical Engineering, University of Kentucky, USA.
Abstract:
Activation sequences during ventricular fibrillation (VF) display complex pattern and fast rate. Recent evidence suggests that even during VF an excitable gap may exist. Existence of excitable gap lead us to hypothesize that it should be possible to entrain activation patterns during VF by using spatially distributed and temporally phased pacing strength stimuli. We describe here the electronics hardware and software that were developed to test our hypothesis. Eight biphasic stimulators were designed and fabricated, each addressable via a TTL input and thus independently triggered. To minimize electrical interference from stimulus pulses the stimulators were optically isolated. A program written in C was used to deliver TTL inputs to time the sequence of stimulation. The parameters that could be varied were, pulse intensity, polarity, and duration, inter pulse interval and activation pattern cycle length. Restitution's of action potential duration, conduction velocity, and complex activation patterns make the timing of stimulators complex. To aid in optimal timing of these stimulators, we used a Luo-Rudy ionic model of cellular activation to simulate VF in a matrix of 400 x 400 cells. Entrainment of activation was verified using animated displays of activation sequences. Using results of simulation we verified the function of our stimulators experimentally using electrically induced VF in canines and by using electrograms recorded from 121-electrode patch. Our results show that the developed hardware and software can be used to deliver distributed stimuli in a flexible and effective pattern, which may aid in development of approaches for treatment of VF.
More Related Videos
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
08:43Advanced Cardiac Rhythm Management by Applying Optogenetic Multi-Site Photostimulation in Murine Hearts
Published on: August 26, 2021
Related Concept Videos
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...
Dysrhythmias VI: Management of Dysrhythmias
Cardiopulmonary Resuscitation IV: Pharmacological Management
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias